Spectrolamps Deuterium Lamp Compatibility List is increasing to include many of the latest models and hard to get deuterium lamps for Atomic Absorbtion Spectrometers, UV-Vis and other detectors. We assemble and prealign with instrument specific brackets and flanges ourselves. Our prices are well below all of our competitors and instrument manufacturers. Contact Us for technical advice and your lamp requirements if not listed.
Please see our deuterium lamps page for lamp pictures.
Manufacturer | Model | Comments | Part Number |
---|---|---|---|
ABI (Applied Biosystems) | Biocad 20 | D027 | |
ABI (Applied Biosystems) | Biocad 60 | D027 | |
ABI (Applied Biosystems) | Biocad 250 | D027 | |
ABI (Applied Biosystems) | Biocad 700E | D027 | |
ABI (Applied Biosystems) | Biocad Spirit | D027 | |
ABI (Applied Biosystems) | Integral 250 | D027 | |
ABI (Applied Biosystems) | Integral 700E | D027 | |
Agilent (HP) | 1080 | Bare lamp | D001 |
Agilent (HP) | 1081 | Bare lamp | D001 |
Agilent (HP) | 1081B | Bare lamp | D001 |
Agilent (HP) | 1084B | Bare lamp | D001 |
Altex / Hitachi | 100 (HPLC) | D002 | |
Altex | 155 | D012 | |
Altex | 163 | D016 | |
Altex | 164 | Bare lamp | D011 |
Altex | 165 | Bare lamp | D011 |
Altex | 167 | Bare lamp | D011 |
Aminco | DW2C | Check terminals | D002 |
Barspec | All Models | D002 | |
BAS | UV116A | D027 | |
BAS | UV200 | D027 | |
Bausch & Lomb | 200 | Use clip from old lamp | D017 |
Bausch & Lomb | 700 | Use clip from old lamp | D017 |
Bausch & Lomb | 710 | Use clip from old lamp | D017 |
Bausch & Lomb | 2000 | Use clip from old lamp | D017 |
Bausch & Lomb | 3100 | D016 | |
Bausch & Lomb | 3200 | D016 | |
Bausch & Lomb | Aquamate UV | D006 | |
Bausch & Lomb | DE 50 | Use clip from old lamp | D017 |
Bausch & Lomb | Genesys 8 | D006 | |
Bausch & Lomb | Spectronic 21 | Use clip from old lamp | D017 |
Bausch & Lomb | Spectronic 21D | Use clip from old lamp | D017 |
Bausch & Lomb | Spectronic 501 | Use clip from old lamp | D017 |
Bausch & Lomb | Spectronic 601 | Use clip from old lamp | D017 |
Bausch & Lomb | Spectronic 1001 | Use clip from old lamp | D017 |
Bausch & Lomb | Spectronic 1001 plus | Use clip from old lamp | D017 |
Bausch & Lomb | Spectronic 1201 | Use clip from old lamp | D017 |
Beckman | 20 | D011 | |
Beckman | 24 | D011 | |
Beckman | 25 | D011 | |
Beckman | 26 | D011 | |
Beckman | 34 | D011 | |
Beckman | 35 | D011 | |
Beckman | 36 | D011 | |
Beckman | 100 | Check terminals | D002 |
Beckman | 155 | D012 | |
Beckman | 163 | D016 | |
Beckman | 164 | D011 | |
Beckman | 165 | D011 | |
Beckman | 167 | D011 | |
Beckman | 5200 | D011 | |
Beckman | Acta | D011 | |
Beckman | DU-6 | D011 | |
Beckman | DU-7 | D011 | |
Beckman | DU-20 | D011 | |
Beckman | DU-30 | D011 | |
Beckman | DU-37 | D011 | |
Beckman | DU-40 | D011 | |
Beckman | DU-50 | D011 | |
Beckman | System Gold | Check terminals | D011 |
Beijing Raleigh Analytical Inst. Co. | UV-1100 | D003 | |
Beijing Raleigh Analytical Inst. Co. | UV-1200 | D003 | |
Beijing Raleigh Analytical Inst. Co. | UV-1300 | D003 | |
Beijing Raleigh Analytical Inst. Co. | UV-1400 | D003 | |
Beijing Raleigh Analytical Inst. Co. | UV-9100 | D003 | |
Biorad | 1790 | D027 | |
Biorad | 1801 | D027 | |
Biorad | Bio-Dimension | D027 | |
Biorad | Bio-Focus 2000 | D027 | |
Biorad | Bio-Focus 3000 | D027 | |
Biorad | CE 2000 | D027 | |
Biorad | HPE 100 | D027 | |
Biorad | Microsampler 100 | D027 | |
Biotronic | BT3035 | Bare lamp | D012 |
Biotronic | BT9510 | Pre-aligned | D027 |
Biotronic | BT9520 | Pre-aligned | D027 |
Carlo Erba | UV-Vis 20 | Pt. No 538711 | D027 |
Carlo Erba | UV-Vis 20 RS | Pt. No 538711 | D027 |
Cecil Instruments | 1000 Series | Pt. No 2202-0142 | D007 |
Cecil Instruments | 2000 Series | Pt. No 2202-0142 | D007 |
Cecil Instruments | 3000 Series | Pt. No 2202-0142 | D007 |
Cecil Instruments | 5000 Series | Pt. No 2202-0142 | D007 |
Cecil Instruments | 6000 Series | Pt. No 2202-0142 | D007 |
Cecil Instruments | 7000 Series | Pt. No 2202-0142 | D007 |
Cecil Instruments | 8000 Series | Pt. No 2202-0142 | D007 |
Cecil Instruments | 9000 Series | Pt. No 2202-0142 | D007 |
Cecil Instruments | CD 4201 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CD 4400 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CD 6600S | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 1010 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 1020 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 1070 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 1200 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 1220 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 2021 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 2202 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 2272 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 2292 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 4200 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 4400 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 5501 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 5502 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 6000 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 6602 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 6603 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 7200 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 8020 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 9020 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 9050 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 9080 | Pt. No 2202-0142 | D007 |
Cecil Instruments | CE 9090 | Pt. No 2202-0142 | D007 |
Cecil Instruments | Series 2 Models | Pt. No 2202-0142 | D007 |
Coleman | 55 | Check terminals | D002 |
Coleman | 124 | Check terminals | D002 |
Coleman | 550 | Check terminals | D002 |
Coleman | 552 | Check terminals | D002 |
Cole-Palmer | 01953-00 | D027 | |
Constametric | Spectromonitor III | D016 | |
Dionex | 4000i | D027 | |
Dionex | DSA-1 | D027 | |
Dionex | VDM-1 | D027 | |
Dupont | 825 | D002 | |
Dupont | 850 | D002 | |
Dynamax | UV-C | D027 | |
Dynamax | UV-D11 | D027 | |
Dynamax | UV-M | D027 | |
EM Science | All | Use old connector | D002 |
Erma | ERC 7210 | Use old connector | D002 |
ESA | 520 | D027 | |
ESA | 522 | D027 | |
Femto | 700 | D017 | |
Femto | 700 Plus | D017 | |
Femto | 700S | D017 | |
Femto | 800XL | D017 | |
GAT | LCD 500 | D027 | |
GAT | LCD 502 | D027 | |
GAT | LCD 503 | D027 | |
GAT | LCD 550 | D027 | |
GAT | PHD 601 | D027 | |
GBC | 906 | D008 | |
GBC | All AA Instruments | D008 | |
GBC | Cintra 6 | D004 | |
GBC | Cintra 10 | D004 | |
GBC | Cintra 20 | D004 | |
GBC | Cintra 40 | D004 | |
GBC | Cintra 101 | D004 | |
GBC | Cintra 202 | D004 | |
GBC | Cintra 303 | D004 | |
GBC | Cintra 404 | D004 | |
GBC | LC 1205 | D027 | |
GBC | LC 1206 | D027 | |
GBC | LC 1210 | D027 | |
GBC | UV 911 | D008 | |
GBC | UV VIS 914 | D004 | |
GBC | UV VIS 916 | D004 | |
GBC | UV VIS 918 | D004 | |
GBC | UV VIS 920 | D004 | |
Gilford | 200 | D001 | |
Gilford | 220 | D001 | |
Gilford | 222 | D001 | |
Gilford | 230 | D001 | |
Gilford | 240 | D001 | |
Gilford | 250 | D001 | |
Gilford | 252 | D001 | |
Gilford | 260 | D001 | |
Gilford | 2000 | D001 | |
Gilford | 2400 | D001 | |
Gilford | 2600 | D001 | |
Gilford | Response | D002 | |
Hewlett Packard | 1080 | Use bracket from old lamp | D001 |
Hewlett Packard | 1081 | Use bracket from old lamp | D001 |
Hewlett Packard | 1081B | Use bracket from old lamp | D001 |
Hewlett Packard | 1082B | Use bracket from old lamp | D001 |
Hewlett Packard | 1084 | Use bracket from old lamp | D001 |
Hewlett Packard | 1084B | Use bracket from old lamp | D001 |
Hitachi | 101 | D012 | |
Hitachi | 102 | D012 | |
Hitachi | 111 | D012 | |
Hitachi | 124 | D002 | |
Hitachi | 181 | Pre-aligned | D005 |
Hitachi | 200 | Pre-aligned | D005 |
Hitachi | 220 | Pre-aligned | D005 |
Hitachi | 220A | Pre-aligned | D005 |
Hitachi | 300 | Pre-aligned | D005 |
Hitachi | 330 | Pre-aligned | D005 |
Hitachi | 330LC | Pre-aligned | D005 |
Hitachi | 340 | Pre-aligned | D005 |
Hitachi | 100-10 | D002 | |
Hitachi | 100-30 | D002 | |
Hitachi | 100-40 | D002 | |
Hitachi | 100-50 | D002 | |
Hitachi | 100-60 | D002 | |
Hitachi | 150-20 | Pre-aligned | D005 |
Hitachi | 655A22 | Pre-aligned | D005 |
Hitachi | 5410 Chromaster | OEM 892-2550 | D005 |
Hitachi | 5420 Chromaster | OEM 892-2550 | D005 |
Hitachi | L-2000 | Pre-aligned | D005 |
Hitachi | L-2500 | Pre-aligned | D005 |
Hitachi | L-3000 | Pre-aligned | D005 |
Hitachi | L-3100 | Pre-aligned | D005 |
Hitachi | L-3200 | Pre-aligned | D005 |
Hitachi | L-4000 | Pre-aligned | D005 |
Hitachi | L-4200 | Pre-aligned | D005 |
Hitachi | L-4225 | Pre-aligned | D005 |
Hitachi | L-4250 | Pre-aligned | D005 |
Hitachi | L-4500 | Pre-aligned | D005 |
Hitachi | L-4520 | Pre-aligned | D005 |
Hitachi | L-4720 | Pre-aligned | D005 |
Hitachi | L-6000 | Pre-aligned | D005 |
Hitachi | L-7000 | Pre-aligned | D005 |
Hitachi | L-7400 | Pre-aligned | D005 |
Hitachi | L-7420 | Pre-aligned | D005 |
Hitachi | L-7450 | Pre-aligned | D005 |
Hitachi | L-7450A | Pre-aligned | D005 |
Hitachi | L-7455 DAD Lachrom | Pre-aligned | D005 |
Hitachi | Lachrom 655A | Pre-aligned | D005 |
Hitachi | U-0080 D | Pre-aligned | D005 |
Hitachi | U-1000 | Pre-aligned | D005 |
Hitachi | U-1100 | Pre-aligned | D005 |
Hitachi | U-1500 | Pre-aligned | D005 |
Hitachi | U-2000 | Pre-aligned | D005 |
Hitachi | U-2001 | Pre-aligned | D005 |
Hitachi | U-3010 | OEM 885-1000 | D005 |
Hitachi | U-3200 | OEM 885-1000 | D005 |
Hitachi | U-3210 | Pre-aligned | D005 |
Hitachi | U-3310 | Pre-aligned | D005 |
Hitachi | U-3410 | Pre-aligned | D005 |
Hitachi | U-3501 | Pre-aligned | D005 |
Hitachi | U-4000 | Pre-aligned | D005 |
Hitachi | U-4001 | Pre-aligned | D005 |
Hitachi | U-4010 | Pre-aligned | D005 |
Hitachi | U-4100 | OEM 885-1000 | D005 |
Hitachi | UL-1100 | Pre-aligned | D005 |
Hitachi / Merck | U-1800 | D015 | |
Hitachi / Merck | U-1900 | D015 | |
Hitachi / Merck | U-2800 | D015 | |
Hitachi / Merck | U-2810 | D015 | |
Hitachi / Merck | U-2900 | D015 | |
Hitachi / Merck | U-2910 | D015 | |
IBM Instruments | Detectors | D016 | |
ICI Instruments | LC1200 | Check terminals | D002 |
Isco | V4 | D001 | |
Jasco | MD 2010 | D003 | |
Jasco | MD 4010 | D003 | |
Jasco | Uvidec 1 | D012 | |
Jasco | Uvidec 100 | D012 | |
Jasco | Uvidec 100 II | D012 | |
Jasco | Uvidec 2 | D012 | |
Jasco | Uvidec 320 | D012 | |
Jasco | Uvidec 340 | D012 | |
Jasco | Uvidec 4 | D012 | |
Jasco | Uvidec 420 | D012 | |
Jasco | Uvidec 4D | D002 | |
Jasco | Uvidec 505 | D012 | |
Jasco | Uvidec 510 | D012 | |
Jasco | Uvidec 710 | D012 | |
Jasco | V-530 | D003 | |
Jasco | V-550 | D003 | |
Jasco | V-560 | D003 | |
Jasco | V-630 | D003 | |
Jasco | V-630 Bio | D003 | |
Jasco | V-650 | D003 | |
Jasco | V-650 PC & IRM type | D003 | |
Jasco | V-660 | D003 | |
Jasco | V-670 | D003 | |
Jasco | 7100 | D003 | |
Jasco | 7850 | D003 | |
Joyce Loebl | Scan 400 | D001 | |
Kontron | Uvikon 725 | D002 | |
Kontron | 725 LC | D002 | |
Laballiance / Scientific Systems | 200 | D027 | |
Laballiance / Scientific Systems | 201 | D027 | |
Laballiance / Scientific Systems | 500 | D027 | |
Laballiance / Scientific Systems | 504 | D027 | |
Laballiance / Scientific Systems | 506 | D027 | |
Laballiance / Scientific Systems | 525 | D027 | |
Laballiance / Scientific Systems | V520 | D027 | |
LDC | 3000 | D016 | |
LDC | 3100 | D016 | |
LDC | 3200 | D016 | |
LDC | 4000 Series | D016 | |
LDC | 4100 | D016 | |
LDC | 4200 | D016 | |
LDC | 5000 | D016 | |
LDC | Spectromonitor 1 | D016 | |
LDC | Spectromonitor 2 | D016 | |
LDC | Spectromonitor 3 | D016 | |
LDC | Spectromonitor 3000 | D016 | |
LDC | Spectromonitor 3200 | D016 | |
LDC | Spectromonitor 4100 | D016 | |
LDC | Spectromonitor D | D016 | |
LDC - Milton Roy | SC 100-234 | D027 | |
LDC - Milton Roy | UV 100-411 | D027 | |
LDC - Milton Roy | UV 150-511 | D027 | |
Linear | 200 | Pt. No 95551-0202 | D027 |
Linear | 201 | Pt. No 95551-0202 | D027 |
Linear | 203 | Pt. No 95551-0202 | D027 |
Linear | 204 | Pt. No 95551-0202 | D027 |
Linear | 205 | Pt. No 95551-0202 | D027 |
Linear | 206 | Pt. No 95551-0202 | D027 |
Linear | 206 PH | Pt. No 95551-0202 | D027 |
Linear | Focus | Pt. No 95551-0202 | D027 |
Linear | Focus 2000 HR | Pt. No 95551-0202 | D027 |
LKB Pharmacia | 4050 | Resolder old circuit board | D002 |
LKB Pharmacia | 4054 | Resolder old circuit board | D002 |
LKB Pharmacia | TDS S/N>205 | Bare lamp | D002 |
LKB Pharmacia | Ultraspec II (S/N>6598) | Resolder old circuit board | D002 |
LKB Pharmacia | Ultraspec III | D002 | |
LKB Pharmacia | Ultraspec Plus (S/N>175) | D002 | |
LKB Pharmacia | Ultraspec+ (S/N>175) | D002 | |
Merck / Hitachi | 655A/22 | Pre-aligned | D005 |
Merck / Hitachi | L3000 | Pre-aligned | D005 |
Merck / Hitachi | L4000 | Pre-aligned | D005 |
Merck / Hitachi | L4500 | Pre-aligned | D005 |
Merck / Hitachi | L4520 | Pre-aligned | D005 |
Merck / Hitachi | L4720 | Pre-aligned | D005 |
Merck / Hitachi | L7400 | Pre-aligned | D005 |
Merck / Hitachi | L7420 | Pre-aligned | D005 |
Merck / Hitachi | L7450 | Pre-aligned | D005 |
Merck / Hitachi | L7455 DAD | Pre-aligned | D015 |
Merck / Hitachi | U-1800 | Pre-aligned | D015 |
Merck / Hitachi | U-2800 | Pre-aligned | D015 |
Merck / Hitachi | U-2810 | Pre-aligned | D015 |
Michrom Bioresources / BRUKER | UV-200 | D027 | |
Michrotech Scientific | Linear MT200 | D027 | |
Michrotech Scientific | Linear MT200 CE | D027 | |
Michrotech Scientific | Linear MT201 | D027 | |
Michrotech Scientific | Linear MT205 | D027 | |
Micromeritics | 787 | D009 | |
Micromeritics | 788 | D009 | |
Micronal | B582 | D003 | |
Milton Roy | 3100 | D016 | |
Milton Roy | 3200 | D016 | |
Milton Roy - Spectronic | 200 | D017 | |
Milton Roy - Spectronic | 700 | D017 | |
Milton Roy - Spectronic | 710 | D017 | |
Milton Roy - Spectronic | 2000 | D017 | |
Milton Roy - Spectronic | 3100 | D016 | |
Milton Roy - Spectronic | 3200 | D016 | |
Milton Roy - Spectronic | DE 50 | D017 | |
Milton Roy - Spectronic | Spectronic 21 | D017 | |
Milton Roy - Spectronic | Spectronic 21D | D017 | |
Milton Roy - Spectronic | Spectronic 501 | D017 | |
Milton Roy - Spectronic | Spectronic 601 | D017 | |
Milton Roy - Spectronic | Spectronic 1001 | D017 | |
Milton Roy - Spectronic | Spectronic 1001 plus | D017 | |
Milton Roy - Spectronic | Spectronic 1201 | D017 | |
NICOLET | Evolution 100 | Pre-aligned | D006 |
NICOLET | Evolution 500 | Pre-aligned | D006 |
NICOLET | Evolution 600 | Pre-aligned | D006 |
Perkin Elmer / Hitachi | 124 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 139 | Bare lamp / check | D002 |
Perkin Elmer / Hitachi | 200 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 220 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 300 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 320 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 329 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 330 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 340 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 556 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 557 | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 220A | PE Pt. 239-0354 | D005 |
Perkin Elmer / Hitachi | 330 LC | PE Pt. 239-0354 | D005 |
Perkin Elmer | 55 | PE Pt. 80055323 | D022 |
Perkin Elmer | 272 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 280 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 360 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 370 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 372 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 373 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 380 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 460 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 550 | PE Pt. 80055323 | D022 |
Perkin Elmer | 551 | PE Pt. 80055323 | D022 |
Perkin Elmer | 552 | PE Pt. 80055323 | D022 |
Perkin Elmer | 552A | PE Pt. 80055323 | D022 |
Perkin Elmer | 553 | PE Pt. 80055323 | D022 |
Perkin Elmer | 559 | PE Pt. 80055323 | D022 |
Perkin Elmer | 559A | PE Pt. 80055323 | D022 |
Perkin Elmer | 560 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 575 | PE Pt. 0057-0194 | D002 |
Perkin Elmer | 603 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 703 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 1100 | D026 | |
Perkin Elmer | 1100 B | D026 | |
Perkin Elmer | 2100 | D026 | |
Perkin Elmer | 2280 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 2380 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 3030 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 3030B | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 4000 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 4100 | D026 | |
Perkin Elmer | 5000 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 5100 | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 5100PC | PE Pt. 0057-0194 | D013 |
Perkin Elmer | 5100Z Leeman | PE Pt. 0057-0194 | D013 |
Perkin Elmer | Analyst 200 | D025 | |
Perkin Elmer | Analyst 400 | D025 | |
Perkin Elmer | Analyst 600 | D026 | |
Perkin Elmer | Analyst 700 | D026 | |
Perkin Elmer | Analyst 800 | D026 | |
Perkin Elmer | EZ 201 | PE Pt. C055-5050 | D002 |
Perkin Elmer | EZ 301 | PE Pt. C055-5050 | D002 |
Perkin Elmer | EZZ201 | Pre-aligned | D005 |
Perkin Elmer | Integral 2000 | PE Pt. C055-5050 | D002 |
Perkin Elmer | Integral 4000 | PE Pt. C055-5050 | D002 |
Perkin Elmer | Lambda 1 | PE Pt. C055-5050 | D002 |
Perkin Elmer | Lambda 2 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 2S | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 3 | PE Pt. C055-5050 | D002 |
Perkin Elmer | Lambda 3A | PE Pt. C055-5050 | D002 |
Perkin Elmer | Lambda 3B | PE Pt. C055-5050 | D002 |
Perkin Elmer | Lambda 4 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 5 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 6 | PE Pt. C055-5050 | D002 |
Perkin Elmer | Lambda 7 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 9 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 10 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 11 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 12 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 14 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 14 P | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 15 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 16 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 17 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 18 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 19 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 20 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 25 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 35 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 40 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 40 P | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 45 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 650 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 750 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 800 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 850 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 900 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 950 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda 1050 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda Bio 19 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda Bio 20 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda Bio 40 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda Bio 800 | PE Pt. 80055323 | D022 |
Perkin Elmer | Lambda Bio 900 | PE Pt. 80055323 | D022 |
Perkin Elmer | LC 55 | PE Pt. 087-1171 | D002 |
Perkin Elmer | LC 55B | D002 | |
Perkin Elmer | LC 65B | D002 | |
Perkin Elmer | LC 65T | D002 | |
Perkin Elmer | LC 75 | D002 | |
Perkin Elmer | LC 85 | D002 | |
Perkin Elmer | LC 85B | D002 | |
Perkin Elmer | LC 95 | PE Pt. 0271-1709 | D002 |
Perkin Elmer | LC 135 | D002 | |
Perkin Elmer | LC 235 | D002 | |
Perkin Elmer | LC 141 MC | D002 | |
Perkin Elmer | LC 241 MC | D002 | |
Perkin Elmer | LC-480 Photo Diode Array | PE Pt. 80055323 | D022 |
Perkin Elmer | M55 | PE Pt. 80055323 | D022 |
Perkin Elmer | M550 | PE Pt. 80055323 | D022 |
Perkin Elmer | M551 | PE Pt. 80055323 | D022 |
Perkin Elmer | M552 ( S/N > 2030 ) | PE Pt. 80055323 | D022 |
Perkin Elmer | M552A | PE Pt. 80055323 | D022 |
Perkin Elmer | M553 | PE Pt. 80055323 | D022 |
Perkin Elmer | M559 | PE Pt. 80055323 | D022 |
Perkin Elmer | M559A | PE Pt. 80055323 | D022 |
Pharmacia | TDS from S/N 206 | Resolder old circuit board | D002 |
Pharmacia | Ultraspec II from S/N 6598 | Resolder old circuit board | D002 |
Pharmacia | Ultraspec III | Resolder old circuit board | D002 |
Pharmacia | Ultraspec Plus from S/N 176 | Resolder old circuit board | D002 |
Severn Analytical | SA6500 | D027 | |
Severn Analytical | SA6503 | D027 | |
Severn Analytical | SA6504 | D027 | |
Severn Analytical | SA6508 | D027 | |
Shanghai Instruments | SP-1900 | D023 | |
Shanghai Instruments | SP-1920 | D023 | |
Shimadzu | 062-65055-05 | OEM Part Number | D003 |
Shimadzu | 6500AA | D001 | |
Shimadzu | AA-625 | D003 | |
Shimadzu | AA-630 | D003 | |
Shimadzu | AA-640 | D003 | |
Shimadzu | AA-660 | D003 | |
Shimadzu | AA-670 | D003 | |
Shimadzu | AA-670G | D003 | |
Shimadzu | AA-680U | D003 | |
Shimadzu | AA-6200 | D003 | |
Shimadzu | AA-6300 | D003 | |
Shimadzu | AA-6500 | D003 | |
Shimadzu | AA-6701 | D003 | |
Shimadzu | AA-6800 | D003 | |
Shimadzu | BioSpec 1601 | D003 | |
Shimadzu | CS-920 | D003 | |
Shimadzu | CS-930 | D003 | |
Shimadzu | CS-9000 | D003 | |
Shimadzu | CS-9301 | D003 | |
Shimadzu | D300L | D003 | |
Shimadzu | LC 3A | D001 | |
Shimadzu | LC 4A | D001 | |
Shimadzu | LC 6A | D001 | |
Shimadzu | MPS 2000 | D003 | |
Shimadzu | MultiSpec 1501 | D003 | |
Shimadzu | SP4 | D001 | |
Shimadzu | SPD-2A | D001 | |
Shimadzu | SPD-6A | D001 | |
Shimadzu | SPD-6AV | D001 | |
Shimadzu | SPD-7A | D001 | |
Shimadzu | SPD-7AV | D001 | |
Shimadzu | UV 106A | D003 | |
Shimadzu | UV 120 | D003 | |
Shimadzu | UV 120-1 | D003 | |
Shimadzu | UV 120-2 | D003 | |
Shimadzu | UV 140 | D003 | |
Shimadzu | UV 140-2 | D003 | |
Shimadzu | UV 150 | D003 | |
Shimadzu | UV 150-2 | D003 | |
Shimadzu | UV 160 | D003 | |
Shimadzu | UV 160A | D003 | |
Shimadzu | UV 163 | D003 | |
Shimadzu | UV 180 | D003 | |
Shimadzu | UV 190 | D003 | |
Shimadzu | UV 200 | D003 | |
Shimadzu | UV 202 | D003 | |
Shimadzu | UV 210 | D003 | |
Shimadzu | UV 210A | D003 | |
Shimadzu | UV 240 | D003 | |
Shimadzu | UV 250 | D003 | |
Shimadzu | UV 260 | D003 | |
Shimadzu | UV 265 | D003 | |
Shimadzu | UV 350 | D003 | |
Shimadzu | UV 360 | D003 | |
Shimadzu | UV 365 | D003 | |
Shimadzu | UV 370 | D003 | |
Shimadzu | UV 625 | D003 | |
Shimadzu | UV 1200 | D003 | |
Shimadzu | UV 1201 | D003 | |
Shimadzu | UV 1201 PC | D003 | |
Shimadzu | UV 1202 | D003 | |
Shimadzu | UV 1240 | D003 | |
Shimadzu | UV 1501 | D003 | |
Shimadzu | UV 1600 | D003 | |
Shimadzu | UV 1601 PC | D003 | |
Shimadzu | UV 1603 | D003 | |
Shimadzu | UV 1650 | D003 | |
Shimadzu | UV 1700 | D003 | |
Shimadzu | UV 1800 | D003 | |
Shimadzu | UV 2100 | D003 | |
Shimadzu | UV 2101 | D003 | |
Shimadzu | UV 2400 | D003 | |
Shimadzu | UV 2401 PC | D003 | |
Shimadzu | UV 2450 | D003 | |
Shimadzu | UV 2500 | D003 | |
Shimadzu | UV 2501 PC | D003 | |
Shimadzu | UV 2550 | D003 | |
Shimadzu | UV 2600 | D003 | |
Shimadzu | UV 2700 | D003 | |
Shimadzu | UV 3000 | D003 | |
Shimadzu | UV 3100 | D003 | |
Shimadzu | UV 3100 PC | D003 | |
Shimadzu | UV 3101 PC | D003 | |
Shimadzu | UV 3600 | D003 | |
Shimadzu | UV 3700 | OEM 200-75503-01 | D003 |
Shimadzu | UV mini 1240 | D003 | |
Shimadzu | UV-Vis 160U | D003 | |
Shimadzu | UV-Vis 190 | D003 | |
Spec Analytical | SA 203 | D027 | |
Spec Analytical | SA 302 | D027 | |
Spectra Physics | 100 | Pt. No 9551-0202 | D027 |
Spectra Physics | 200 | Pt. No 9551-0202 | D027 |
Spectra Physics | CE 100 | Pt. No 9551-0202 | D027 |
Spectra Physics | CE 500 | Pt. No 9551-0202 | D027 |
Spectra Physics | CE 1000 | Pt. No 9551-0202 | D027 |
Spectra Physics | CE 2000 | Pt. No 9551-0202 | D027 |
Spectra Physics | Focus detector | Pt. No 9551-0202 | D027 |
Spectra Physics | Spectrachrom 100 | Pt. No 9551-0202 | D027 |
Spectra Physics | Spectrachrom 200 | Pt. No 9551-0202 | D027 |
Spectra Physics | UV 100 | Pt. No 9551-0202 | D027 |
Spectra Physics | UV 150 | Pt. No 9551-0202 | D027 |
Spectra Physics | UV 1000 | Pt. No 9551-0202 | D027 |
Spectra Physics | UV 2000 | Pt. No 9551-0202 | D027 |
Spectra Physics | UV 3000 | Pt. No 9551-0202 | D027 |
Spectra Physics | UV 3000 HR | Pt. No 9551-0202 | D027 |
Spectra Physics | 3100 | D016 | |
Thermo Scientific | Aquamate | Pre-aligned | D006 |
Thermo Scientific | Evolution 600 | Pre-aligned | D006 |
Thermo Scientific | SC 100 | D027 | |
Thermo Scientific | SC 200 | D027 | |
Thermo Scientific | Spectra 100 | D027 | |
Thermo Scientific | Spectrachrom 100 | D027 | |
Thermo Scientific | Spectrachrom 200 | D027 | |
Thermo Scientific | Spectro Monitor 3200 | Use clip from old lamp | D017 |
Thermo Scientific | UV1 | Pre-aligned | D006 |
Thermo Scientific | UV1-100 | Pre-aligned | D006 |
Thermo Scientific | UV2 | Pre-aligned | D006 |
Thermo Scientific | UV3 | Pre-aligned | D006 |
Thermo Scientific | UV4 | Pre-aligned | D006 |
Thermo Unicam | 4225 | D027 | |
Thermo Unicam | Aquamate UV | Pre-aligned | D006 |
Thermo Unicam | Biomate 5 | Pre-aligned | D006 |
Thermo Unicam | Evolution 6000 | Pre-aligned | D006 |
Thermo Unicam | Genesys 8 | Pre-aligned | D006 |
Thermo Unicam | Helios Alpha | Pre-aligned | D006 |
Thermo Unicam | Helios Beta | Pre-aligned | D006 |
Thermo Unicam | Helios Delta | Pre-aligned | D006 |
Thermo Unicam | Helios Epsilon | Pre-aligned | D006 |
Thermo Unicam | Helios Gamma | Pre-aligned | D006 |
Thermo Unicam | Helios II | Pre-aligned | D006 |
Thermo Unicam | Solar S4 | Pre-aligned | D010 |
Thermo Unicam | Solaar 929 | D014 | |
Thermo Unicam | Solaar 939 | D014 | |
Thermo Unicam | Solaar 959 | D014 | |
Thermo Unicam | Solaar 969 | D014 | |
Thermo Unicam | SP7500 | D017 | |
Thermo Unicam | UV1-100 | Pre-aligned | D006 |
Thermo Unicam | UV2-100 | Pre-aligned | D006 |
Thermo Unicam | UV2-200 | Pre-aligned | D006 |
Thermo Unicam | UV2-300 | Pre-aligned | D006 |
Thermo Unicam | UV2-400 | Pre-aligned | D006 |
Thermo Unicam | UV3-100 | Pre-aligned | D006 |
Thermo Unicam | UV3-200 | Pre-aligned | D006 |
Thermo Unicam | UV4-100 | Pre-aligned | D006 |
Thermo Unicam | UV4-200 | Pre-aligned | D006 |
Thermo Unicam | UV4-500 | Pre-aligned | D006 |
Thermo Unicam | UV300 | Pre-aligned | D006 |
Thermo Unicam | UV500 | Pre-aligned | D006 |
Thermo Unicam | UV550 | Pre-aligned | D006 |
Tosoh | 8010 | D016 | |
Tosoh | 8011 | D016 | |
Varian | 75 Series | Varian Pt. 56-100218-00 | D009 |
Varian | 2300 | Varian Pt. 56-100218-00 | D009 |
Varian | AA200 | Varian Pt. 56-100218-00 | D009 |
Varian | AA220 | Varian Pt. 56-100218-00 | D009 |
Varian | AA240 | Varian Pt. 56-100218-00 | D009 |
Varian | AA275 | Varian Pt. 56-100218-00 | D009 |
Varian | AA280 | Varian Pt. 56-100218-00 | D009 |
Varian | AA300 | Varian Pt. 56-100218-00 | D009 |
Varian | AA400 | Varian Pt. 56-100218-00 | D009 |
Varian | AA475 | Varian Pt. 56-100218-00 | D009 |
Varian | AA600 | Varian Pt. 56-100218-00 | D009 |
Varian | AA640 | Varian Pt. 56-100218-00 | D009 |
Varian | AA775 | Varian Pt. 56-100218-00 | D009 |
Varian | AA800 | Varian Pt. 56-100218-00 | D009 |
Varian | AA875 | Varian Pt. 56-100218-00 | D009 |
Varian | AA975 | Varian Pt. 56-100218-00 | D009 |
Varian | AA1275 | Varian Pt. 56-100218-00 | D009 |
Varian | AA1475 | Varian Pt. 56-100218-00 | D009 |
Varian | AA3000 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 1 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 3 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 4 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 5 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 50 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 100 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 210 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 219 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 220 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 300 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 400 | Varian Pt. 56-100218-00 | D009 |
Varian | Cary 500 | Varian Pt. 56-100218-00 | D009 |
Varian | DMS 70 | Varian Pt. 56-100218-00 | D009 |
Varian | DMS 80 | Varian Pt. 56-100218-00 | D009 |
Varian | DMS 90 | Varian Pt. 56-100218-00 | D009 |
Varian | DMS 100 | Varian Pt. 56-100218-00 | D009 |
Varian | DMS 200 | Varian Pt. 56-100218-00 | D009 |
Varian | DMS 300 | Varian Pt. 56-100218-00 | D009 |
Varian | LC 9050 | Use bracket from old lamp | D018 |
Varian | ProStar 310 | Use bracket from old lamp | D018 |
Varian | ProStar 340 | D027 | |
Varian | ProStar 345 | D027 | |
Varian | Spectra 800 | Varian Pt. 56-100218-00 | D009 |
Varian | Spectra A10 | Varian Pt. 56-100218-00 | D009 |
Varian | Spectra A20 | Varian Pt. 56-100218-00 | D009 |
Varian | Spectra A30 | Varian Pt. 56-100218-00 | D009 |
Varian | Spectra A40 | Varian Pt. 56-100218-00 | D009 |
Varian | Spectra A640 | Varian Pt. 56-100218-00 | D009 |
Varian | Spectra A880 | Varian Pt. 56-100218-00 | D009 |
Varian | Spectro AA 220FS | Varian Pt. 56-100218-00 | D009 |
Varian | UV-C | D027 | |
Varian | UV-DII | D027 | |
Varian | UV-M | D027 | |
Varian | UV Superscan | Varian Pt. 56-100218-00 | D009 |
Varian | UV-50 | Use bracket from old lamp | D018 |
Varian | UV-100 | Use bracket from old lamp | D018 |
Varian | UV-200 | Use bracket from old lamp | D018 |
Varian | UV 634 | Varian Pt. 56-100132-00 | D012 |
Varian | UV 635 | Varian Pt. 56-100132-00 | D012 |
Varian | Vista 5000 | Use bracket from old lamp | D018 |
Varian | Vista 5500 | Use bracket from old lamp | D018 |
Waters | 480LC | D016 | |
Waters | 481 | Use bracket from old lamp | D016 |
Waters | 481LC | D016 | |
Waters | 996 | D024 | |
Waters | 2996 | D024 | |
Waters | Lambda max | D016 |